Back

Owners manual (pdf)

Signal Acquisition System 

* Bandwidth: 100 MHz
* Sample Rate: 500 MS/s on each channel

* Channels: two identical channels, each with invert function

* Sensitivity: 2 mV to 10 V/div

* Vertical Resolution: 8 bits (256 levels over 10.24 vertical divisions)

 

Time Base System (Main and Delayed)

* Time/Division Range: 5 ns - 5 s/div

* Record Length: 1000 sample points per channel

Triggering System (Main Only)

* Triggering Types: Edge, Video Automatic Measurements

Option 14 (I/O Interface): Computer Interface and Hardcopy Capability * GPIB (IEEE-488.2) Programmability * RS-232 Interface

 

Programmability

* Video Output

* Hardcopy Port - Centronics-type parallel or RS-232

* Graphics Interface File Formats - Interleaf (.img), TIFF, PCX (PC Paintbrush), BMP (Microsoft Windows), and Encapsulated Postscript (EPS)

* Printer Formats - ThinkJet, DeskJet, LaserJet, Epson (9 & 24 Pin), Seiko DPU 411/II, DPU 412. DC power provided for Seiko printers

Mäter en attack på en rör-kompressor.
Kompressorn har en dålig kondensator i nätdelen som ger rippel på vågen.